Los gastos de envío se calculan en la pantalla de pago.
Meet the ERAYAK 4500PDM dual-fuel inverter generator. Choose gasoline or propane, enjoy reliable manual recoil starting, and power compatible RV appliances, camping equipment and selected household essentials. Automatic propane-to-gasoline switchover provides additional operating flexibility.
Gasoline and propane flexibility meets reliable manual recoil starting in a portable 120V inverter generator.
Two fuel choices for travel, camping and portable backup. No natural-gas capability.
A straightforward pull-start system for gasoline or propane operation. Follow the manual's fuel and choke procedure.
Connect compatible 30A RV power cords through the included L5-30P to TT-30R adapter and the generator's L5-30R outlet.
Designed to transition from propane to gasoline when propane pressure becomes insufficient, provided usable gasoline is available.
Inverter technology delivers power suitable for many compatible electronics and appliances.
A 30A locking receptacle, dual 20A household outlets and an included RV adapter provide practical connections for 120V equipment.
One 120V 30A locking outlet for compatible electrical equipment and 30A RV connections using the included adapter.
Two household-style outlets for compatible appliances, portable electronics, camping equipment and tools.
The included L5-30P to TT-30R adapter allows a standard compatible 30A RV power cord to connect to the generator's L5-30R outlet.
Choose gasoline or propane based on your operating needs, then plan for the different running and peak ratings.
Up to 3,500W of rated output, with up to 4,500W temporary peak output for compatible starting requirements.
Up to 3,150W of rated output, with up to 4,050W temporary peak output. Connected loads must fit propane's lower power rating.
The L5-30R receptacle has a 30A rating at 120V. Actual continuous output remains limited to the selected fuel's rated generator power.
The 4500PDM is designed to transition from propane to gasoline when propane pressure falls below its operating requirement, provided usable gasoline is available in the tank and the required operating conditions are met. Monitor fuel supply and connected electrical loads.
Important: 4,500W gasoline peak and 4,050W propane peak are temporary ratings, not continuous power. Individual outlet ratings do not increase total generator output. The available capacity is shared across all outlets. Check motor starting surge, running power and selected fuel before adding loads.
Portable dual-fuel performance for RV camping, outdoor activities, electronic devices and selected 120V household backup needs.
Compatible 30A RV setups
Lighting and outdoor comforts
Selected 120V backup loads
Portable power and lighting
TVs, laptops and charging
Explore 10 common appliances and tools, ranked by estimated starting or maximum input watts. Check actual running and starting requirements for your equipment, especially when operating on propane.
Power Planning Note: All wattages are illustrative planning estimates, not guaranteed specifications for particular appliance models. For motor-driven equipment, peak values represent possible starting demand. For heating appliances, maximum input power is shown instead. Actual startup requirements may vary significantly with motor size, design and operating conditions. The ERAYAK 4500PDM provides 4,500W peak / 3,500W running on gasoline and 4,050W peak / 3,150W running on propane. A load near the generator's peak rating may not start reliably, particularly with other equipment already connected. Verify appliance voltage, actual running and starting watts, receptacle ratings, breaker limits and total connected load before use.
The 4500PDM uses a manual recoil starting system. It does not include electric or remote starting. Follow the specified gasoline or propane startup procedure.
With the 2.25 gal gasoline tank, published runtime is up to 12 hours at 25% load or 8 hours at 50% load under specified conditions.
With a 20 lb propane tank, published runtime is up to 12 hours at 25% load, 8 hours at 50% load or 5 hours at full load.
Engine oil capacity: 0.6L / 600mL. Check oil level before use, and follow the owner's manual for oil, air filter and spark plug maintenance.
Low-oil and overload protection help protect the generator. The parallel connection interface should be used only with compatible approved parallel equipment.
Runtime Test Conditions: Published runtime figures are based on specified operating conditions at approximately 77°F (25°C). Actual runtime varies with load, altitude, fuel quality, temperature and maintenance. Refer to the owner's manual for starting procedures, service intervals and safety instructions.
The included L5-30P to TT-30R adapter allows a compatible 30A RV power cord to connect to the generator's 120V L5-30R locking outlet.
Choose gasoline or propane and prepare the fuel system according to the owner's manual. If relying on automatic propane-to-gasoline switchover, make sure usable gasoline is available in the tank.
With the generator stopped and RV electrical loads off, insert the included L5-30P to TT-30R adapter into the generator's L5-30R outlet. Connect a compatible 30A RV power cord.
Start the generator using the manual recoil procedure. Allow electrical output to stabilize, then add RV loads gradually. Stay within the selected fuel's continuous power rating.
RV Compatibility: The L5-30P to TT-30R adapter is intended for compatible 120V 30A RV connections. It does not create 240V output, provide full 50A RV service or increase the generator's available electrical power. RV air conditioner compatibility depends on compressor starting surge and total connected load.
Operate the generator outdoors only, at least 20 ft from doors, windows and vents, with exhaust directed away from occupied buildings. Never operate inside an RV, tent, house, garage, shed or any enclosed or partially enclosed space. Use working carbon monoxide alarms inside occupied areas. Keep the generator dry and do not operate in rain, standing water or flooding. Connect propane cylinders, hoses and regulators according to the owner's manual. Check all fuel connections for leaks using approved methods. Never refuel gasoline while the generator is running or hot. Use appropriately rated cords, adapters and electrical connections. Never backfeed household wiring through a wall outlet. Disconnect or turn off connected loads before shutdown. Always follow the current ERAYAK owner's manual and applicable electrical and fuel safety requirements.
El envío demora entre 3 y 10 días hábiles, dependiendo de su región.
Sí, las devoluciones y cambios son posibles dentro de los 14 días posteriores a la recepción del pedido.
Una vez enviado, recibirás un número de seguimiento para seguir tu paquete.
Comuníquese con nuestro equipo de soporte: reemplazaremos el artículo o emitiremos un reembolso.